faq
You are here: Home  »  Products  »  Steam Boilers
gas-condensing-steam-boiler

Automatic WNS Series Oil Gas Fired Condensing Steam Boiler

Scan the QR code
WNS series horizontal internal combustion boiler is a boiler shell type 3 passes wetback oil/gas fired boiler. After fuel is being atomized by burner, flame is full of the wave furnace and transfer heat via furnace wall, this is 1st pass; the high temperature smoke is collected in reversal chamber and then enters 2nd pass which is grooved tubes bundle area; after heat convection, air temperature gradually falls and goes to front smoke box and turn to 3rd pass, which is smooth tubes bundle area, and then enters chimney passing back smoke box and exhausted to the atmosphere.
Share to:
Condensing Steam Boiler Introduce
Technical Parameter

WNS series horizontal internal combustion boiler is a boiler shell type 3 passes wetback oil/gas fired boiler. After fuel is being atomized by burner, flame is full of the wave furnace and transfer heat via furnace wall, this is 1st pass; the high temperature smoke is collected in reversal chamber and then enters 2nd pass which is grooved tubes bundle area; after heat convection, air temperature gradually falls and goes to front smoke box and turn to 3rd pass, which is smooth tubes bundle area, and then enters chimney passing back smoke box and exhausted to the atmosphere.


Fuel: Natural gas, Diesel oil

Rated Evaporation: 1-20T/h

Rated Steam Pressure: 1.25/1.6 Mpa

Rated Steam Temperature: 194/204℃

Designed Heat Efficiency: 100.2%-100.5%

Available fuel: Nature gas, coke oven gas, biogas, methanol, liquid propane gas, diesel, heavy oil, light oil, crude oil, etc.

Available industries: Heat supplying, chemical, food, textile, printing and dyeing, cigarettes and tobacco, fodder, pharmacy, building materials, brewery, rubber, hospital etc

 

Main Features

1. The boiler use horizontal full wet back structure with high thermal efficiency.

2. Micro positive pressure operation effectively improves the combustion intensity of the furnace, eliminates the air leakage of the furnace and flue of the boiler, and improves the thermal efficiency of the boiler.

3. The external independent condenser uses the currently popular condensation technology to reduce the exhaust temperature and improve the thermal efficiency.

4. Using advanced EDA design technology, detailed calculation of furnace structure and size, effective control of flue gas flow rate and resistance, reasonable and full use of flame and gas heat exchange, improve the boiler's thermal efficiency.

5. The corrugated furnace liner structure not only increases the heating area but also increases the disturbance of flue gas, The threaded smoke pipe technology increase the convection heating surface.

6. Using frequency conversion water supply and control technology to ensure the condensation rate of water vapor in the flue gas.

7. The condenser is made of special steel with "sulfuric acid resistance and low dew point corrosion resistance", which greatly improves the service life.

gas-steam-condensing-steam-boiler

WNS Series Oil Gas Fired Condensing Steam Boiler Technical Parameter:

 
Model WNS1 WNS1.5 WNS2 WNS3 WNS4 WNS6 WNS8 WNS10 WNS15 WNS20
Rated Evaporation t/h 1 1.5 2 3 4 6 8 10 15 20
Rated Steam Pressure Mpa 1.25(1.6)
Rated Steam Temp. 194(204)
Rated Inlet Water Temp. 20 20(104)
Heating Area Of Boiler Body m2 19.3 27.9 36.5 54.8 62.3 112 125 165 237 290
Energy Saver Heating Area m2 5.9 8.9 11.9 19.9 25.6 32.5 42.3 48.9 85.5 109
Condenser heating area m2 7.9 13.9 19.9 25 32.2 43.6 56.6 81.9 150 192
Designed Heat Efficiency % 100.3 100.2 100.2 100.3 100.2 100.2 100.2 100.2 100.5 100.4
Designed Ambient Temperature 20
Weight T 4.8 6.5 7.8 8.8 11.6 14.1 17.9 21.8 31 38
Boiler Operating Water Volume T 3.1 4 5.2 6.8 9 12.8 16.3 20.7 30.5 37.1
Boiler Full Water Volume T 3.6 4.5 6.1 7.9 10.5 14.4 19.4 24.1 34.1 41
Boiler Water Supply Method   Positional Water Supply Proportional Water Supply
Burning Method   Micro Positive Pressure Chamber Combustion
Natural Gas Nm3/h 70.2 105.6 140.5 211.1 281.4 422.1 562.5 705.6 1055.4 1410.1
Diesel Oil Kg/h 60.4 90.2 121.4 181.1 239.5 362.1 479.6 601.5 902.8 1205.1
Transportation Size L mm 3850 4080 4250 4690 5250 6100 6210 6853 7430 7890
W 1900 2000 2100 2350 2540 2600 2920 3110 3550 3750
H 2110 2240 2450 2580 2800 2980 3280 3460 3800 4050
Installation Size L mm
 
4630 4750 5100 5680 6350 7450 7700 8230 9380 9700
W 2800 2990 3000 3250 3440 3500 3820 4010 4350 4550
H 3200 3560 3720 3850 4120 4350 5000 5200 5600 6100
Water Inlet DN mm 32 32 40 40 40 40 50 50 65 65
Main Steam Outlet DN mm 50 65 100 80 100 125 150 150 200 200
Secondary Steam Outlet DN mm 32 32 40 40 40 50 50 50 50 50
Manual Sewage Outlet DN mm 40 40 50 50 50 50 2*50 2*50 3*50 3*50
Continuous Sewage Outlet DN mm -- -- -- -- -- -- -- 40 40 40
Safety Valve DN mm 2*40 2*40 2*40 2*50 2*50 2*65 2*80 2*80 2*100 2*150
Chimney Diameter mm Ø300 Ø 350 Ø 400 Ø 450 Ø 500 Ø 600 Ø 700 Ø 800 Ø 1000 Ø 1200
Remark 1: Above all data according to standards of natural gas low position calorific value8400kcal/Nm, diesel low position calorific value 10250kcal/kg.
Remark 2: Due to continuous improvement, we reserve the right to modify the appearance& specifications. The above parameters are for reference only, please refer to the final drawing.
Product Inquiry